Light Sources>> Wavelength Calibration Sources>>HG-1 Mercury Argon Calibration Source for UV-VIS  

HG-1 Mercury Argon Calibration Source


The compact, low-cost HG-1 Mercury Argon Calibration Source is a spectral wavelength calibration source for UV-VIS-Shortwave NIR spectrophotometric systems. The HG-1 produces first order mercury and argon spectral lines from 253-922 nm and second order argon lines to 1700 nm for use in performing fast, reliable spectrometer wavelength calibrations. Easily identifiable mercury and argon spectral emission lines are printed on the HG-1 housing.

The HG-1 is available for

With the HG-1 and an Ocean Optics spectrometer, users can perform wavelength calibration with a spreadsheet program such as Microsoft Excel or a calculator that performs linear regressions. For technical assistance in performing the latter option, click on Calibrating the Wavelength of Your Spectrometer.

The HG-1 features an SMA 905 Connector to couple to Ocean Optics spectrometers and fiber optic accessories, including optical fibers. The HG-1 operates with a 12 VDC power supply (included with the unit) or 9V battery (not included).

User's Tip: Ocean Optics spectrometers are carefully calibrated as part of the company's standard quality assurance process. However, as is the case with all spectrometers, wavelength will drift slightly due to time and environmental conditions. If wavelength accuracy is an important part of your work, consider including calibration spectra with every experiment.

Specifications

Output:

Low-pressure gas discharge lines of mercury and argon

Spectral range:

253-1700 nm

Dimensions (in mm):

125.7 x 70 x 25.8

Power consumption:

250 mA at 12 VDC

Power requirements:

12 VDC wall transformer (included) or
9 VDC battery (additional)

Internal voltage:

600 volts at 30 kHz

Bulb life:

~ 3,500 hours (at 20 mA)

Amplitude stabilization:

~1 minute

Aperture:

3 mm

Connector:

SMA 905

User's Tip: Ocean Optics recommends using the HG-1 with a 50 µm-diameter or smaller optical fiber or entrance slit. The use of  fibers and slits >50 µm in diameter will result in optical resolution (full width, half maximum) that adversely affects wavelength calibration. Also, keep in mind that if the spectrometer has no slit and your experiment involves using optical fibers of different diameters, wavelength re-calibration will be required. That's because optical resolution will vary according to the diameter of the fiber in use -- i.e., a 50 µm fiber will resolve differently than a 100 µm fiber, and so on. Recalibration is also recommended every time that you unscrew the fiber from the SMA 905 Connector on the spectrometer.

Spectral Output

Mercury emission lines are <600 nm. Argon emission lines are >600 nm, and are shown here on an exaggerated amplitude scale.

Strong Hg Emission Lines by Wavelength (nm)

User's Tip: There are more emission lines published here than printed on the label on the HG-1 housing. The label is intended as a quick, convenient reference and does not list every Ar or Hg emission line that exists.

253.652 404.656
296.728 407.783*
302.150 435.833
313.155 546.074**
334.148 576.960
365.015 579.066

* This spectral line will not be evident with spectrometers configured with 300- or 600-lines/mm gratings.

** With spectrometers that have 1200-, 1800-, 2400- or 3600-lines/mm gratings, spectral lines will be evident at 576.96 nm and 579.07 nm.

Strong Ar Emission Lines by Wavelength (nm)

696.543 800.616*
706.722 811.531
714.704 826.452
727.294 842.465
738.398 852.144
750.387 866.794
763.511 912.297
772.376 922.450
794.818

* This spectral line will be evident only with spectrometers configured with 1800-, 2400-, or 3600-lines/mm gratings.

Cuvette Wavelength Calibration Adapter

The PS-HG1-ADP Wavelength Calibration Adapter is a 1-cm square fixture that fits into a 1-cm pathlength sample chamber and connects to the HG-1 via optical fiber. (Neither wavelength calibration standard or fiber is included). The adapter is designed for performing a wavelength calibration for any spectrometer and 1-cm cuvette holder system, whether it's designed by Ocean Optics or another manufacturer.

 
版權(quán)所有 2007 廣州標旗光電科技發(fā)展股份有限公司 www.zxbwrq.cn
地址:廣州市黃埔區(qū)彩頻路7號701-1房
電話:(020)38319602 38319620 傳真:(020)38319595 ICP備案:粵ICP備2024341827號 粵公網(wǎng)安備44011202002999
主站蜘蛛池模板: 生化危机启示录2| 电影《森林》| 老爸老妈浪漫史第一季| 女人打架视频| 镍多少钱一公斤| 电影《kiskisan》在线播放| 电视剧狂飙演员名单| 地铁电影| 法医秦明之幸存者 2018 经超| 次强音| 女同性电影| 文琪演过的电视剧有哪些| 2024年月历| 欧美日韩欧美日韩在线观看视频| 公司辞退员工的合法流程及赔偿| 龙岭迷窟演员表| 天与地越南战争在线观看免费| 家书1000字| 任喜宝| 张柏芝惊艳照片| 女神异闻录3动漫| 一千零一夜凯瑟林| 演觉法师| 甜蜜高潮 第一季 电视剧| 孕妇直播肚子疼揉肚子| 挠vk| 小姐诱心国语未删减版| 一年又一年电视剧演员表| 帕巴拉呼图克图| 国产电影网站| 护士诱惑| 山上的小屋 残雪原文| 黑马配白马成功的视频| 缝鞋子针法视频| 吻胸亲乳激情大尺度| 男同性恋| 小恩雅骑马舞蹈视频| 失落的星球| 欧美xxxx做受性欧美蜜臀av| 今天cctv6节目表| 美丽的邂逅|